Victron BlueSolar MPPT 150V/70A-Tr (12/24/36/48V-70A) Charge Controller
Victron Energy – BlueSolar Series
Featured Highlights:
• Ultra-fast Maximum Power Point Tracking (MPPT)
• Advanced Maximum Power Point Detection in case of partial shading conditions
• Outstanding conversion efficiency
• Flexible charge algorithm
• Extensive electronic protection
• Internal temperature sensor
• Real-time data display options
Extensive electronic protection: Over-temperature protection and power derating when the temperature is high. PV short circuit and PV reverse polarity protection. PV reverse current protection.
Description
BlueSolar Charge Controller MPPT 150/70-Tr
Specifications:
Battery voltage: 12/24/48V Auto Select
Rated charge current: 70A
Maximum PV power, 12V 1a,b): 1000W
Maximum PV power, 24V 1a,b): 2000W
Maximum PV power, 48V 1a,b): 4000W
Maximum PV short circuit current 2): 50A
Maximum PV open circuit voltage: 150V absolute maximum coldest conditions – 145V start-up and operating maximum
Maximum efficiency : 98%
Self-consumption: 10 mA
Charge voltage ‘absorption’: Default setting: 14,4/28,8/43,2/57,6V (Adj.)
Charge voltage ‘float’: Default setting: 13,8/27,6/41,4/55,2V (Adjust.)
Charge algorithm: multi-stage adaptive
Temperature compensation: -16 mV/-32 mV/-68mV/ °C
Protection: Battery reverse polarity (fuse-not user accessible)
PV reverse polarity/Output short circuit/Over temperature
Operating temperature: -30 to +60°C (full rated output up to 40°C)
Humidity: 95%, non-condensing
Data communication port and remote on-off: VE.Direct
*See the data communication white paper ~Victron Energy website*
Parallel operation: Yes (not synchronized)
ENCLOSURE
Colour: Blue (RAL 5012)
PV terminals 3): 35 mm² / AWG2 (Tr models)
Two sets of MC4 connectors (MC4 models up to 150/170)
Three sets of MC4 connectors (MC4 models 150/85 and 150/100)
Battery terminals: 35mm²/ AWG2
Protection cat.: IP43 (electronic components), IP22 (connection area)
Weight: 3.8 Kg
Dimensions (h x w x d) in mm: Tr models: 185 x 250 x 95
MC4 models: 215 x 250 x 95
STANDARDS
Safety EN/IEC 62109
1a) If more PV power is connected, the controller will limit input power to the stated maximum.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V
2) A PV array with a higher short-circuit current may damage the controller.
3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels. Maximum current per MC4 connector: 30A