BlueNova – BN13V-310-4k Classic – Lithium Iron Yttrium Phosphate – 13V
Charge/Discharge:
Bulk Voltage: 14.1 VDC
Discharge Voltage (min.): 11.6 V
Charge Current (max.): 250 A continuous
Discharge Current (max.):
- 250 A continuous,
- 320 A burst (1 minute)
- 500 A peak ( 2 seconds)
Self-discharge Rate: < 2% per month
Charge & Discharge Efficiency: 96% @C2 ; 98% @C10
Protection:
Thermal Isolator: 320 A
In-line Fuse: 2 x 125 A
Over-current Protection: 250 A
Over-voltage Cut-out: 15.6 V (3.90 V on any cell)
Under-voltage Cut-out: 11.4 V (2.85 V on any cell)
Description
MasterController™ Features:
-
On-board display for monitoring performance variables, such as cell voltage & temperature.
- Integrated energy meter.
-
Serial communication (CANBUS) compatible with leading inverters.
Other Features:
-
Automatic pre-charge circuit.
-
Built-in fuse & DC isolator.
-
10 year warranty.